Basic Thermostat Wiring Part 2

When you have a call for cooling from the thermostat the R terminal on the thermostat is connected internally to the terminal labeled G. The wire typically connected to the G terminal is green and it connects to the G terminal on the circuit board.  When this terminal receives 24 V input from the thermostat it energizes a relay on the circuit board starting the indoor fan. At the same time R is connected to terminal G it also connects to the terminal labeled Y on the thermostat. This terminal is typically connected to a Yellow or Blue wire depending on what brand of thermostat wire was used during installation. This wire will connect to a terminal on the circuit board labeled Y. This terminal is only a junction point on the circuit board. It does not connect to anything internally on the board. There will be one other connection on the circuit board labeled C. This terminal is connected back to the common terminal on the 24 V side of the transformer and is placed there for connecting the 24 V power to the outdoor unit. When the thermostat calls for cooling 24 V power will be available at Y and C on the circuit board. There will be a separate thermostat wire bundle with a wire running from each of these terminals to a contactor coil in the outdoor unit.

Basic Thermostat Wiring Part 1

On a basic gas furnace and air conditioning system the thermostat control circuit is a simple design. The transformer steps the line voltage down to 24 VAC. When you are checking this circuit the volt meter needs to be set up for AC not DC. The primary side of the transformer should have an input of 120 VAC. The secondary terminals should have an output of 24-28 VAC. If you do not have 120 VAC between the 2 primary terminals you will not have an output voltage. If you do have input voltage between the primary terminals and 0 volts between the secondary terminals the transformer has failed. This indicates an issue in the 24 V circuit that must be addressed. Otherwise the new transformer will fail as soon as power is applied. One of the secondary terminals on the transformer will be connected to one side of all of the operating devices such as contactors, relays, circuit boards. The other secondary terminal supplies the R terminal on the thermostat. The thermostat acts like a switch to turn everything on for operation.

When you have a call for heat the thermostat closes a switch connecting R from the transformer to W on the thermostat. This sends power through all the safety switches to the circuit board to start the fan and to the gas valve to light the burners. Common practice is to connect the red thermostat wire to R and the white thermostat wire to W. The circuit board has a time delay built in to allow the burner to start generating heat before starting the fan. When the thermostat reaches temperature and shuts off the gas valve another time delay is initiated to allow the fan to run and cool down the furnace. This is why we do not recommend aftermarket circuit boards. The timing has been determined by the manufacturer for optimum life and efficiency of the furnace and the algorithm is proprietary to the equipment manufacturer. Using a true OEM board can prevent premature failure of your equipment.

Checking Amps

Amp readings are useful when checking the condition of a motor. In the picture below we are checking the amp draw of a functioning motor that is not giving us any problems. Note the clamp has been placed around one power wire feeding the motor. The thumbwheel was turned to AC Amps before placing the meter clamp around the wire. Always set your meter properly before connecting. This motor has a FLA (Full Load Amp) rating of .5 A  If the motor is drawing more than that there is an issue that needs to be corrected. It could be bad bearings, bad capacitor, incorrect motor, incorrect fan blade, loose wiring.  If the motor is drawing over the FLA the motor will overheat and shut off. This motor is drawing .4 A so it is in good operating condition.

Motor amps

Electric Meters

Electric meters are the best tool you can use to troubleshoot your furnace or air conditioner as most failures that the average do it yourself person attempts are of an electrical nature. When you purchase a meter I strongly recommend purchasing one with a CAT III 600 V rating. If a meter is connected incorrectly or not set in the correct mode it can explode. Cat III ratings mean the meter has fusing inside it to prevent meter damage and operator injuries. If it does inadvertently get connected incorrectly and the fuse blows it must be replaced with the specified fuse in order to maintain the safety of the meter. A cheaper meter has a very good chance of causing severe injuries to the novice.

The picture listed below shows a Fluke 333 meter which is CAT III 600 V rated. The top of the meter is a clamp that spreads open and clamps back together for taking amp readings. There is a thumbwheel in the center of the meter for the different testing functions. Below the thumbwheel is a window where the readings are displayed. On the bottom of the meter are 2 ports. The left port is black and the right port is red. The ports are where the meter leads plug in for taking readings.

This meter can be used to read Alternating Current (AC) Amps, Ohms, Direct Current (DC) Volts and AC Volts.

Electric Meter

Information About Capacitors

There are 2 different types of capacitors used in the HVAC field. The types are start capacitor and run capacitor.

A start capacitor is called a start capacitor because it is in operation only when the motor is starting. This design increases the torque of the motor allowing a compressor to start against a load. This design is not used with a fan motor. It is used in conjunction with some type of relay that removes it from the circuit as a motor approaches full speed. This type of capacitor is encased in a bakelite case and is air cooled. It is not filled with oil and it is usually a round design.

The most common type of capacitor is a run capacitor. It is designated as a run capacitor because it stays in the circuit while the motor is operating. The purpose of a run capacitor is to increase motor starting torque as well as increasing the efficiency of the motor during operation. This capacitor is in a plastic or metal can and is filled with oil. The purpose of the oil is to help cool the internal plates during operation. This capacitor can be either round or oval shape.

Understanding Basic System Operation

A common basic air conditioning system and gas furnace application  consists of a gas furnace located inside the building with an evaporator coil and a condensing unit located outside the building usually at ground level. The gas furnace blower is used to circulate the air over the evaporator coil where it is cooled and distributed through the building via the duct system. The gas furnace has a transformer inside the control panel that reduces the 120 volt power supplied to the furnace to 24 volts used for the control power. The 24 volts is sent to the thermostat where it is switched to turn equipment on and off as required by the temperature inside the building. On a call for cooling the thermostat has 2 circuits that are energized. It will supply control voltage back to some type of device that turns on the blower motor. It also supplies control voltage to the outdoor unit to energize it. These are two totally separate circuits so that gives you a clue during troubleshooting. If the indoor fan and the outdoor unit are both off you should suspect either a loss of 24 volts from the transformer or a bad thermostat or thermostat wire. If the outdoor unit is operating and the indoor fan is not you will need to troubleshoot the fan circuit. If the indoor fan is operating and the outdoor unit is not then most likely the issue is in the outdoor unit.

Run Capacitor Identification

The best way to identify the correct capacitor is using the correct nomenclature from the HVAC equipment nameplate. Getting the correct factory part will keep your UL listing intact and you will know your equipment is operating at factory specs. Sometimes the tag is not legible on older units. I have added an image showing the tag on 2 different brands of capacitors. The information required for replacement is the uf rating and the VAC rating. As you can see there are 2 different ways to list the information used by 2 different manufacturers. In the image the capacitor on the left lists the uf ratings as 50/5 uf and 440 VAC. The capacitor on the right lists the same ratings as 50 uf     5 uf and 440VAC.

Capacitor1

The capacitors we show in the picture are manufactured for Carrier Corporation with a Carrier part number on each one. The capacitor on the right has Carrier part number HC98KA051D. The D in this part  number is not used so the actual part number is HC98KA051. This part number has been replaced by Carrier with a new part number. New part number P291-5054RS is the factory replacement for HC98KA051. If you provide the product number from the Carrier equipment you are servicing we have access to a Carrier database that lists the current Carrier part number for all parts used in your equipment. By providing the product number you can be assured you will get a brand new Carrier factory part and your equipment will be operating at its original specs and efficiency.

Run Capacitors

Run capacitors used in HVAC applications can be either round or oval shape. They also can be either a single or dual capacitor. A single capacitor has one set of plates and is used for the operation of one motor. A dual capacitor is actually two capacitors in one shell sharing a common plate. Dual capacitors are used for the operation of two motors. The two different type of capacitors can be differentiated by the terminals on top. A single capacitor will have  two terminals and a dual capacitor will have three terminals on top. The two internal capacitors share a common plate for both motors labeled C on the top of the capacitor. The other terminals will be labeled FAN for the fan motor and HERM for the compressor. It is very important to make sure the wires go back on the same terminals when replacing a capacitor. A capacitor can fail and cause the fan motor and compressor not to start. The top of the capacitor should be perfectly flat. If it is slightly domed or has any type of oil leak it should be changed. Bad bearings in a fan motor can cause a capacitor to fail. Capacitor failures are very common during heat waves as excess heat does cause damage. Make sure power has been disconnected before making any repairs. In the picture below the capacitor on the right is slightly domed. Notice the flat top on the new capacitor on the left. Also notice the terminals are clearly marked.

Capacitor